TECHNE  INSTRUMENTS

Tecal 140S/H
TECAL Dri-Block Calibrators

Amprobe Model AM-20, 21 & 22 This temperature calibrator is ideal for calibrating temperature sensors used in the food and pharmaceutical industries as well as calibrating any sensors used in the temperature range outlined in the specification below.

The Tecal 140S provides a complete system for calibrating most types of thermal sensors used in the temperature range of -40°C to 140°C which includes "K" type thermocouples commonly used in the food industries, cold storage rooms and environmental monitoring systems.

Where automation in both the field and laboratory are required, the combination of the Tecal 140H with the UPI saves time and money. The user can set the program and leave the unit to calibrate the probes, automatically storing the results in memory. This allows the user to attend to other tasks and when convenient download the results to a computer to print the calibration certificate.

Using advanced peltier technology and state-of-the-art mechanical and electrical components, these calibrators can rapidly cover the complete temperature range where speed is of the essence without loss of accuracy or stability. A metal block with a defined measuring zone of 50mm from the bottom of the block allows for different length/active area sensors. Although the quoted accuracy and stability is ±0.3°C & ±0.05°C respectively, one can often achieve an accuracy of ±0.1°C and a stability of ±0.02°C with high class RTDs and thermocouples.

Technical Data 140 S/H
Minimum temperature 45°C below ambient*
Maximum temperature 140°C
Temperature Accuracy in measuring zone +/-0.3°C**
Temperature Uniformity in measuring zone +/-0.2°C
Measuring zone +0 to 50mm from base of well
Temperature stability after 10mins +/-0.05°C
Display resolution 0.1°C
Heating rate 20°C to 100°C 5 mins
Cooling rate100°C to 0°C 9 mins
Programmable ramp rate, °C/min 0.1 to 10
Switch test on H version
Comms port, 9 way D type Full bi-directional RS232
Weight, kg 14 (S), 14.4 (H)
Dimensions HxWxD mm 285x190x426

* In a maximum ambient temp of 20°C and when using the CH5 Chiller a temp of -40°C can be achieved.
**At 100°C


Please Request Quote or Information  >>>  Click Here!


Shopping Around?  Talk To Us!

** Listed above are most of this company's products --
Please ASK about any products that you don't see here.

Models: INF*, INFC*, INCD*, Q8000P, Q9000*, Q2000*, Q3000*, 2002B-*, 3002-*, 202A-*, 508B, 509, 558B, IDP, DRN*, DRX*, 205P, ICN*, INFCH, INFP*, 2520-PA, P6000, P5000, 2004*, 2003b*, 201AN-AC, L2*, L4*, 6155A*, OS520E, OS523, OS524, OS550, OS1551, OS1552, OS1553, RP*